Tutorial for MasterPlex
®
CT v1.0
© 2006 Hitachi Software Engineering America, Ltd. All Rights Reserved.
Przeglądanie stron 0
1 2 3 4 5 6 ... 46 47

Podsumowanie treści

Strona 1

Tutorial for MasterPlex® CT v1.0 © 2006 Hitachi Software Engineering America, Ltd. All Rights Reserved.

Strona 2

http://www.miraibio.comPlex CT 10 Here is the breakdown and a brief summary of the wizards:  The Startup Wizard walks you through the warm up and

Strona 3

http://www.miraibio.comPlex CT 11 Please note that there are detailed instructions provided at each step. The next window checks to make sure that

Strona 4

http://www.miraibio.comPlex CT 12 In the next step of the Startup Wizard, you can perform the Prime procedure. Priming removes air bubbl

Strona 5

http://www.miraibio.comPlex CT 13 The next step takes you through the Alcohol Flush, which removes air bubbles from the cuvette. In this step, you

Strona 6 - Thumbwheel

http://www.miraibio.comPlex CT 14 You are now done with the Startup Wizard and your Luminex system is ready for use. After finishing one wizard,

Strona 7

http://www.miraibio.comPlex CT 15 Action List Manager The Action List Manager lets you customize and automate routine procedures such as Startup, Ma

Strona 8

http://www.miraibio.comPlex CT 16 Next, we want to specify the number of times a step is to be repeated and the well location for the ope

Strona 9

http://www.miraibio.comPlex CT 17 Lastly, we will name our newly created Action List to “Startup Procedure” in the Action Name form and press the S

Strona 10

http://www.miraibio.comPlex CT 18

Strona 11

http://www.miraibio.comPlex CT 19 Three Step Acquisition MasterPlex CT v1.0 allows just three simple steps to run an acquisition: 1) What – Spe

Strona 12

http://www.miraibio.comPlex CT 2

Strona 13

http://www.miraibio.comPlex CT 20 Let’s begin with the Region settings. First click the Region Modify button to activate appropriate regions. Th

Strona 14

http://www.miraibio.comPlex CT 21 To define bead region names, click on the Properties tab. Next, double-click the default name und

Strona 15 - Remove Item button

http://www.miraibio.comPlex CT 22 Now, let’s enter our parameters that will determine how the machine will run by clicking the Setup Modify button.

Strona 16

http://www.miraibio.comPlex CT 23 In the Setup tab, you can specify the Double Discriminator gate values, the direction of which the acquisition

Strona 17

http://www.miraibio.comPlex CT 24 To mark your sample wells, you can simply drag and click to highlight wells or hold down the CTRL key to select

Strona 18

http://www.miraibio.comPlex CT 25 Congratulations! You have now completed the 3 steps needed to begin data acquisition. You have entered your: 1)

Strona 19

http://www.miraibio.comPlex CT 26 Master

Strona 20

http://www.miraibio.comPlex CT 27 Kit Manager MasterPlex CT has built-in capabilities to recognize predefined kit configurations so that you will n

Strona 21

http://www.miraibio.comPlex CT 28 You can use this Kit Manager to:  Import new kit files  View general information about a kit  Duplicate a

Strona 22

http://www.miraibio.comPlex CT 29 The Plate Map tab displays background, standard, and control sample locations. The Regions tab

Strona 23

http://www.miraibio.comPlex CT 3 In this tutorial, we will be highlighting 8 powerful features of the MasterPlex CT v1.0 software: 1) Probe Hei

Strona 24

http://www.miraibio.comPlex CT 30 The Samples tab displays the information regarding the standards, negative controls and quality control sampl

Strona 25

http://www.miraibio.comPlex CT 31 Click on the Cancel button to close the Lot Information window and then press the Apply button to use the kit co

Strona 26

http://www.miraibio.comPlex CT 32

Strona 27

http://www.miraibio.comPlex CT 33 Seamless Integration MasterPlex CT seamlessly integrates with other MasterPlex analysis packages such as MasterP

Strona 28

http://www.miraibio.comPlex CT 34 The analysis program you have chosen automatically launches. If you have used a kit configuration file, all

Strona 29

http://www.miraibio.comPlex CT 35 Select the data type pull menu and view the Concentration data. All the unknown concentrations for each

Strona 30

http://www.miraibio.comPlex CT 36 To view the Standard Curve graph, click on the Standard Curve button. To view the x-axis in log scale, rig

Strona 31

http://www.miraibio.comPlex CT 37 To view multiple standard curves in the same graph, hold down the CTRL key and select the reg

Strona 32

http://www.miraibio.comPlex CT 38 MasterPlex CT has many different options to view data. For example, to view a graph in 3-D, click on the 3D b

Strona 33

http://www.miraibio.comPlex CT 39 Fail Safe Acquisition With MasterPlex CT, your data acquisition need not be “all or nothing.” The Fail Safe Acqu

Strona 34

http://www.miraibio.comPlex CT 4

Strona 35

http://www.miraibio.comPlex CT 40 While the data is being reprocessed, the data is presented in the same view as if it was being acquired in real

Strona 36

http://www.miraibio.comPlex CT 41 If you discover that you are not using optimal settings during the run, cl

Strona 37

http://www.miraibio.comPlex CT 42

Strona 38

http://www.miraibio.comPlex CT 43 Remote Monitor Free yourself from the instrument. MasterPlex CT includes a remote client program that allows yo

Strona 39

http://www.miraibio.comPlex CT 44 In case of an emergency, the Luminex instrument can be remotely paused by just simply clicking on the Pause but

Strona 40

http://www.miraibio.comPlex CT 45 In the Data tab, you can view MFI data as it is being acquired well-by-well in real-time. In the Co

Strona 41

http://www.miraibio.comPlex CT 46 In the Device tab, you can monitor the status of the Luminex instrument. In the abo

Strona 42

http://www.miraibio.comPlex CT 47 You can also contact MiraiBio with any questions you have at (510) 337-2000 (USA phone number) or by sending an e

Strona 43

http://www.miraibio.comPlex CT 5 Probe Height Adjustment Being able to adjust the probe height is crucial for any Luminex user as it is the cause

Strona 44

http://www.miraibio.comPlex CT 6 Thumbwheel Bolt The initial Adjust Probe window gives detailed instructions on adjusting the probe he

Strona 45

http://www.miraibio.comPlex CT 7 4. After you have placed the appropriate alignment tools into the well, press the Location button and specify the

Strona 46

http://www.miraibio.comPlex CT 8

Strona 47

http://www.miraibio.comPlex CT 9 Wizard Interface MasterPlex CT provides a set of wizard driven interfaces to help familiarize new users with the s